A fire monitor—also called a fire truck water cannon or vehicle-mounted monitor—is a core component of modern fire truck apparatus. It discharges high-volume water streams or firefighting foam, helping firefighters suppress fires in high-rise buildings, industrial facilities, and other areas that are difficult to approach directly or present significant safety risks.

But choosing the right fire monitor is not simply a matter of picking the model with the longest range or the highest flow rate. Should your fire truck use a manual, electric, or remote-control monitor? How much flow do you actually need? What is the difference between common models like PL8/24, PL8/32, and PL8/48? This article explains the key selection factors and compares three common foam-water fire monitors to help fire departments, apparatus manufacturers, and equipment buyers make informed decisions.
Manual fire monitors are operated on-site by handwheel or handle—simple, reliable, and low-cost, suited for attended positions with moderate fire risk. Electric fire monitors use motor-driven actuators controlled from the cab or a wired panel—they keep operators away from heat and smoke. Remote-control fire monitors add wireless operation, preset positions, and automatic detection integration—essential for high-risk, access-prohibited zones.

A manual fire monitor relies on a handle, lever, or handwheel to achieve horizontal rotation and vertical elevation. Its structure is simple, and it is widely used on conventional fire trucks.
Key characteristics:
Simple operation and mechanical structure
Operates in power-outage conditions or remote areas
Lower purchase and maintenance cost
Suitable for fire trucks where the monitor position is easily accessible
When to choose: Small to medium warehouses, docks, pump stations, and other attended positions where fire risk is moderate and personnel access is safe.
Limitation: The manual monitor has a single point of failure—someone must be at the monitor position. If the area is too dangerous to approach, the monitor cannot be operated.
An electric fire monitor uses motor-driven mechanisms for horizontal and vertical movement. Operators typically adjust the monitor through a wired joystick, control panel, or integrated vehicle control system.
Key characteristics:
Motor-driven adjustment with faster response and higher precision
Operator stays in the cab or at a safe distance
Easy integration with vehicle control systems
Some models support preset positions and automatic oscillating spray
When to choose: Medium to large industrial facilities, chemical plants, and locations where manual operation would expose personnel to heat, smoke, or toxic fumes.
Limitations:
Requires a dedicated power supply
More complex installation and wiring
Motors and control components require regular inspection and maintenance


A remote-control fire monitor adds wireless operation and can integrate with fire detection systems for automatic activation.
Key characteristics:
Greater operator positioning flexibility with long-distance wireless operation
More convenient firefighting in hazardous environments
Automatic activation via fire alarm system integration
Status feedback to the control room
Can operate in both automatic and manual modes
When to choose: Petrochemical plants, oil tank farms, LNG terminals, tunnels, and any facility where personnel cannot safely approach the monitor position.
After determining the control method, the next step is to evaluate hydraulic performance. There are two core parameters: flow rate and jet range.
Flow rate refers to the volume of extinguishing medium passing through the monitor per second, measured in liters per second (L/s). A higher flow rate delivers more extinguishing medium, but places greater demand on the fire pump and water supply system.
Before selecting, confirm:
Fire pump output capacity at the monitor's rated working pressure
Available water or foam solution reserves
Pressure loss through pipes, valves, and fittings
Water consumption from other simultaneously open discharge outlets
Intended firefighting application

Jet range refers to the distance the extinguishing medium travels under specified test conditions. A longer range is advantageous for high-rise buildings, large warehouses, industrial installations, and fire zones that firefighters cannot approach closely.
However, catalog range does not equal performance under all conditions. Actual performance is affected by:
Available pressure at the monitor inlet
Nozzle structure and jet pattern
Elevation angle
Wind conditions
Water or foam jetting characteristics
The optimal monitor is the one that covers the target fire area within the vehicle's hydraulic capability.
Once the control method and hydraulic requirements are determined, specific models can be compared. PL8/24, PL8/32, and PL8/48 are common water-foam dual-purpose monitors with different rated flow rates.
Model numbering explained: The number 8 represents the rated working pressure of 0.8 MPa (8 bar), and the final number represents the rated flow rate (L/s). The table below shows reference parameters for standard manual PL series monitors.
| Parameter | PL8/24 | PL8/32 | PL8/48 |
| Rated flow rate | 24 L/s | 32 L/s | 48 L/s |
| Water jet range | ≥55 m | ≥60 m | ≥70 m |
| Foam jet range | ≥42 m | ≥48 m | ≥60 m |
| Horizontal rotation | 360° | 360° | 360° |
| Working pressure | 0.8–1.6 MPa | 0.8–1.6 MPa | 0.8–1.6 MPa |
The PL8/24 monitor has a rated flow of 24 L/s at 0.8 MPa. Reference performance:
Water jet range ≥55 m
Foam jet range ≥42 m
Rated flow 1,440 L/min


The PL8/32 monitor has a rated flow of 32 L/s at 0.8 MPa. Reference performance:
Water jet range ≥60 m
Foam jet range ≥48 m
Rated flow 1,920 L/min


The PL8/48 monitor has a rated flow of 48 L/s at 0.8 MPa. Reference performance:
Water jet range ≥70 m
Foam jet range ≥60 m
Rated flow 2,880 L/min


Water monitors (PS series) are only suitable for Class A fires—wood, paper, plastics, and general combustibles. Foam-water dual-purpose monitors (PL series) are essential for Class B fires—petroleum products, solvents, and flammable liquids.
Selection recommendations:
• Only Class A fire risk (e.g., ordinary warehouses, wood processing plants): Water monitor (PS series) may be selected
• Class B fire risk exists (e.g., petrochemical plants, oil depots, gas stations, airports): Foam-water dual-purpose monitor (PL series) is required
• Both Class A and Class B fire risks: Foam-water dual-purpose monitor is preferred for compatibility with both fire scenarios
Q1: What is the difference between a manual and an electric fire monitor?
A: Manual fire monitors are operated on-site by handwheel or handle, requiring an operator to be present at the monitor position. Electric fire monitors use motor-driven actuators controlled from the cab or a wired panel, keeping the operator at a safe distance.
Q2: When should I choose a remote-control fire monitor?
A: Choose remote control when personnel cannot safely approach the monitor position—such as petrochemical plants, oil tank farms, or tunnels. Remote-control monitors can also integrate with fire detection systems for automatic activation.
Q3: What does the number in PL8/32 mean?
A: The number indicates the rated flow rate in liters per second. PL8/32 has a rated flow of 32 L/s. A higher number means greater flow and longer jet range.
Q4: Can a water monitor be used for oil fires?
A: No. Water cannot suppress a burning liquid surface—it either evaporates or sinks beneath the fuel. Class B fires (petroleum products and flammable liquids) require a foam-water dual-purpose monitor (PL series).
Q5: What is the maximum remote-control distance for a fire monitor?
A: Wireless remote-control distance typically exceeds 150 meters, depending on the specific model and operating environment.
Q6: How do I choose between PL8/24, PL8/32, and PL8/48?
A: The choice depends on your fire pump capacity and the fire risk level. PL8/24 is suitable for light to medium fire trucks and medium-sized fires. PL8/32 is suitable for medium fire trucks and large industrial fires. PL8/48 is suitable for heavy fire trucks and major tank farm protection.
Choosing the right fire monitor for your fire truck is about matching the equipment to the fire risk, not just matching the budget. For control method, manual monitors suit attended positions, electric monitors offer cab-controlled operation, and remote-control monitors are essential for high-risk or access-prohibited zones. For flow rate, PL8/24 suits medium fires, PL8/32 suits large industrial fires, and PL8/48 suits major tank farm protection. For extinguishing medium, water monitors (PS series) are only for Class A fires, while foam-water dual-purpose monitors (PL series) are essential for Class B flammable liquid fires.